• Skip to primary navigation
  • Skip to main content
TM Hughes Electrical

TM Hughes Electrical

Domestic & Commercial Electricians Based In Essex

  • Home
  • Electrical Services
    • Consumer Units
    • Earthing & Bonding
    • Landlords Electrical Inspections & Certificates EICR
    • Lighting Design & Installation
    • Rewiring
    • Smoke, Heat & Carbon Monoxide Alarms
    • Sockets & Switches
    • Landlord & Letting Agent Services
  • Plumbing & Heating
  • Areas A-G
    • Basildon
    • Benfleet
    • Billericay
    • Braintree
    • Brentwood
    • Buckhurst Hill
    • Canvey Island
    • Chelmsford
    • Chigwell
    • Danbury
    • Doddinghurst
    • Epping
    • Grays
    • Great Notley
  • Areas H-Z
    • Hockley
    • Hullbridge
    • Hutton
    • Ingatestone
    • Leigh On Sea
    • Loughton
    • Maldon
    • North Weald
    • Ongar
    • Rayleigh
    • Rochford
    • Shenfield
    • Southend
    • South Woodham Ferrers
    • Wickford
    • Witham
  • FAQ
    • Consumer Unit FAQ
    • EICR FAQ
    • Rewiring FAQ
    • Electrical Safety & Compliance
    • Landlord Electrical Compliance
  • About
    • About Us
    • Blog
  • Contact Us
  • Call – 01245 830560

Smoke, Heat & Carbon Monoxide Alarms for Landlords

Landlords in England are legally required to have at least one smoke alarm on each floor (which has a room used as living accommodation) of their rental properties.

CO alarms are required in any room which is used as living accommodation and contains a fixed fuel-burning appliance (apart from gas cookers). Heat alarms may also be required depending on the property and its fire safety requirements.

Our NICEIC-registered electricians fit, test, and replace alarms in rental properties throughout Essex.

What are the legal alarm requirements for landlords?

The Smoke and Carbon Monoxide Alarm (England) Regulations 2015 were amended in October 2022. The amendments extended the carbon monoxide alarm requirements and clarified landlords’ responsibilities if an alarm is faulty.

Under the regulations, landlords must:

  • Provide a smoke alarm on every floor which is used as living accommodation.
  • Provide carbon monoxide alarms in the rooms where they are required.
  • Check that the required alarms are all functioning on day one of each new tenancy.
  • Investigate reported alarm faults.
  • Repair or replace any faulty alarms ASAP once a fault has been confirmed.

Local authorities can issue fines of up to £5,000 for non-compliance with a remedial notice.

Smoke Alarm Requirements for Landlords

Smoke alarms detect smoke and alert tenants. Early detection gives the tenant more time to get out of the property.

When installing smoke alarms, consider:

  • The number of floors in the property.
  • Hallways, landings and escape routes.
  • The size and layout of each floor.
  • Whether any further alarms are needed.
  • The manufacturer’s installation instructions.

Smoke alarms are normally fitted to the ceiling. In larger properties, you may benefit from additional alarms in the bedrooms and living room.

BS 5839-6 is the British Standard for fire detection and alarm in domestic properties. It’s a guide for electricians when selecting appropriate alarm systems based on the property and its fire risks.

Heat Alarm Requirements for Landlords

Heat alarms respond to a change in temperature rather than to smoke. They’re the alarm you want in the kitchen where cooking will inevitably set off a smoke alarm.

Although landlords are not obliged to fit heat alarms in every kitchen under the general alarm regulations, it’s recommended as good practice.

Heat alarms may however be required under:

  • Building Regulations for new homes.
  • Building Regulations for certain alterations to property.
  • HMO licensing conditions.
  • Property-specific fire safety requirements.

A heat alarm cannot be used as a substitute for a smoke alarm as required under the landlord alarm regulations.

Our electricians can come and assess your rental property and advise you on the best positions for smoke and heat alarms.

Carbon Monoxide Alarm Requirements for Landlords

Carbon monoxide (CO) is a poisonous gas which is colourless, odourless and tasteless. It is produced when fuel burns in an oxygen-deficient atmosphere.

Carbon monoxide alarms are required in rooms used as living accommodation containing fixed combustion appliances, including:

  • Gas boilers
  • Gas fires
  • Oil-fired boilers
  • Wood-burning stoves
  • Open solid fuel fires.

Gas cookers are exempt from that requirement under the landlord alarm regulations. There may be further fire and gas safety requirements in place, though.

The HSE recommend that you select carbon monoxide alarms which meet BS EN 50291.

Follow the manufacturer’s instructions when positioning the CO alarms. Don’t put them behind any furniture, curtains or other obstructions.

Are carbon monoxide alarms part of a landlord gas safety check?

Carbon monoxide alarm requirements and the landlord’s gas safety inspection are covered by separate legislation.

A Landlord Gas Safety Record (CP12 certificate) will record the results of the annual gas safety inspection. A current CP12 does not confirm that the property complies with all carbon monoxide alarm requirements.

Landlords must also meet their gas safety and maintenance duties, including:

  • Annual landlord gas safety inspections.
  • Safe maintenance of gas appliances and flues.
  • Boiler servicing in accordance with the manufacturer’s recommendation.
  • Gas fire servicing where applicable.
  • Installation and maintenance of the required carbon monoxide alarms.

You can arrange your gas safety inspections, servicing and repairs via our sister company TM Hughes & Son Gas Services Ltd.

Together, our companies make it easier to get electrical and gas safety work done under one roof.

Do rental properties need mains-powered or interlinked alarms?

The general landlord alarm regulations don’t specify whether the alarm has to be battery-powered or mains-powered.

Alarm options include:

  • Battery-powered alarms with replaceable batteries.
  • Sealed long-life battery alarms.
  • Mains-powered with battery backup.
  • Wired interlinked alarms.
  • Wireless interlinked alarms.

Interlinked alarms provide a greater degree of protection than individual alarms. If one of the interlinked smoke or heat alarms detects a fire, it will sound all of the other alarms.

If a fire starts in the kitchen at night, the alarms upstairs will also sound. The sleeping tenant will get an earlier warning than if they were just relying on the kitchen alarm.

The benefits of interlinked alarm systems include:

  • Earlier warnings all the way through the property.
  • Better protection for sleeping tenants.
  • More time for tenants to get the hell out.
  • Improved fire detection coverage on a number of floors.
  • The ability to link compatible smoke and heat alarms.

Although interlinked alarms aren’t a legal requirement in every rental property, it’s good fire safety practice to have them.

Building Regulations, HMO licensing conditions and other fire safety requirements will dictate what type of alarm system is required.

Our NICEIC-registered electricians can come and assess your rental property and then recommend an appropriate alarm system in line with the layout of the property, the number of occupants and the fire safety requirements.

Alarm Requirements for Houses in Multiple Occupation (HMOs)

Houses in multiple occupation generally require a more extensive fire detection and alarm system.

Depending on the property, requirements may include:

  • Smoke alarms in bedrooms and communal areas.
  • Heat alarms in kitchens.
  • Mains-powered interlinked alarms.
  • Central fire alarm control panels.
  • Recorded alarm testing and maintenance.

Requirements will vary depending on the property layout, the number of occupants, and the applicable fire safety rules.

Check your local authority’s HMO licensing conditions prior to fitting or upgrading any alarms.

Who is responsible for testing and replacing the alarms?

Landlords must ensure that smoke and carbon monoxide alarms work at the start of each new tenancy.

Essex County Fire and Rescue Service recommend that smoke alarms are tested at least once a month.

During a tenancy, tenants should:

  • Test the alarms
  • Report any faulty or damaged alarms.
  • Replace removable batteries where applicable.
  • Keep the alarms clear of any obstruction.
  • Don’t disconnect or disable the alarms.

If a tenant reports a fault, the landlord must investigate. Any alarms found to be faulty must be repaired or replaced ASAP.

When should landlords replace their smoke, heat and carbon monoxide alarms?

Smoke, heat and carbon monoxide alarms all have a limited working life. Replacement intervals vary by manufacturer and model.

Check your alarms for:

  • Expired replacement dates.
  • Failed alarm tests.
  • Physical damage.
  • Persistent fault warnings.
  • Faulty sensors.
  • Signs of tampering.

Check the replacement date printed on each alarm. Changing the batteries won’t extend the life of an alarm that’s past its expiry date.

Alarm Checks Between Tenancies and During EICRs

The period between tenancies is the time to go through the existing alarms and do any required upgrades.

Your property checklist should include:

  • Checking alarm locations.
  • Checking alarm replacement dates.
  • Testing individual alarms and the interlinked systems.
  • Replacing failed, expired or missing alarms.
  • Recording alarm checks.
  • Check the required alarms on day one of the new tenancy.

An Electrical Installation Condition Report (EICR) covers the fixed electrical installation, including the relevant mains-powered alarm supply circuits.

However, an EICR doesn’t replace the need for separate alarm testing or confirm compliance with all relevant fire safety regulations.

For more information on your electrical safety duties, please see our Essex landlord electrical safety guide.

Smoke, Heat and Carbon Monoxide Alarm Installation for Essex Landlords

TM Hughes & Son Electrical Services Ltd provide smoke, heat and CO alarm fitting throughout Essex.

Our NICEIC-registered electricians will install, test, replace and upgrade alarms in both occupied and unoccupied rental properties.

You can also arrange your EICRs, electrical repairs and consumer unit upgrades via our fully insured electrical company.

Our landlord and letting agent services cover both individual rental properties and larger portfolios. Gas, heating, plumbing and general property maintenance are all available via our sister company.

Get in touch by phone, email or WhatsApp to discuss your property’s alarm requirements, and we’ll arrange a free survey and quote.



Get A Price Now

Call – 01245 830560

Email Us

terry-hughes

Hi, I’m Terry, the founder and owner of TM Hughes & Son Electrical Services

Please get in touch to book an appointment or receive a free, no-obligation quote

Call: 01245 830560

Email: info@tmhugheselectrical.co.uk

Copyright © 2026 TM Hughes & Son Electrical Services Ltd | Company No: 11129865 | Registered In England & Wales | VAT: 339 6207 85 | Built by Roysearch

  • Privacy & Cookie Policy
  • Terms & Conditions
  • Facebook
  • Instagram
  • Linkedin
  • Google Maps
  • X
Manage Cookie Consent
To provide the best experiences, we use technologies like cookies to store and/or access device information. Consenting to these technologies will allow us to process data such as browsing behavior or unique IDs on this site. Not consenting or withdrawing consent, may adversely affect certain features and functions.
Functional Always active
The technical storage or access is strictly necessary for the legitimate purpose of enabling the use of a specific service explicitly requested by the subscriber or user, or for the sole purpose of carrying out the transmission of a communication over an electronic communications network.
Preferences
The technical storage or access is necessary for the legitimate purpose of storing preferences that are not requested by the subscriber or user.
Statistics
The technical storage or access that is used exclusively for statistical purposes. The technical storage or access that is used exclusively for anonymous statistical purposes. Without a subpoena, voluntary compliance on the part of your Internet Service Provider, or additional records from a third party, information stored or retrieved for this purpose alone cannot usually be used to identify you.
Marketing
The technical storage or access is required to create user profiles to send advertising, or to track the user on a website or across several websites for similar marketing purposes.
  • Manage options
  • Manage services
  • Manage {vendor_count} vendors
  • Read more about these purposes
View preferences
  • {title}
  • {title}
  • {title}